When it comes to guaranteeing security in industrial, commercial, and residential areas, slip resistance testing is an important factor. At ATTAR (Advanced Technology Testing & Research), we focus on floor slip resistance testing, concrete moisture testing, and luminance contrast analysis to assist businesses and property owners reduce dangers and abide by security requirements.
With state-of-the-art equipment such as the pendulum slip test device and moisture meter for concrete, we offer precise and independent slip testing services throughout Australia. Our expertise covers ASTM F2170 compliance, R Ranking assessments, P Rating tiles, and more, ensuring your floors satisfy the greatest security standards.
Why Slip Resistance Testing is Necessary
Slips and falls are amongst the leading causes of workplace and public injuries. Proper slip testing helps determine harmful surface areas before mishaps take place. Whether you require damp pendulum test examinations or pendulum test for slip resistance, ATTAR provides accurate outcomes to improve safety.
Key Services Provided by ATTAR
1. Floor Slip Resistance Testing
- Pendulum slip test (AS 4663).
- R Score and P Score tiles assessments.
- Independent slip testing services for compliance.
2. Concrete Moisture Testing
- Slab moisture test using sophisticated moisture meter for concrete.
- ASTM F2170 compliant assessments.
- Concrete slab moisture testing to prevent flooring failures.
3. Luminance Contrast Testing
- Ensures visibility for visually impaired individuals.
- Complies with Australian accessibility standards.
4. On-Site & Laboratory Testing
- Slip test maker for precise on-site evaluations.
- Wet pendulum test for wet surface area slip resistance.
Comprehending Slip Resistance Rankings: R Ranking vs. P Ranking
When performing slip resistance testing, 2 essential classifications are used:.
- R Ranking (Ramp Test - DIN 51130)
Procedures slip resistance under lubricated conditions, typically used in Europe.
- P Rating (Pendulum Test - AS 4586)
Examines vibrant friction using a pendulum test slip resistance machine, extensively embraced in Australia.
ATTAR offers independent slip testing to determine whether your floor covering fulfills the required pendulum rating tiles requirements.
The Significance of Concrete Moisture Testing
Excess moisture in concrete slabs can cause floor covering failures, mold development, and adhesive deterioration. Our concrete moisture testing services include:.
> ASTM F2170 compliant in-situ relative humidity testing.
> Moisture meter for concrete assessments.
> Slab moisture test to make sure ideal conditions for floor installations.
By detecting moisture concerns early, we help prevent expensive repairs and make sure long-lasting flooring efficiency.
Luminance Contrast for Accessibility Compliance
Correct luminance contrast is important for visually impaired people to navigate areas safely. ATTAR examines:.
> Stair edges.
> Door frames.
> Handrails.
> Tactile signs.
Our assessments make sure compliance with Australian Disability Standards (AS 1428.1).
Why Pick ATTAR for Slip Resistance & Moisture Testing?
> NATA Accredited (where appropriate).
> Advanced Testing Devices (pendulum slip test, moisture meters).
> Nationwide Service Coverage.
> Quick & Trustworthy Reporting.
For expert slip resistance testing, floor slip resistance testing, and concrete moisture testing, contact ATTAR (Advanced Technology Testing & Research):.
Address: 44/48 Rocco Dr, Scoresby VIC 3179, Australia.
Phone: +61 1300 139 155.
Typical Applications of Slip Resistance Testing
1. Commercial & Retail Spaces
Shopping centres, dining establishments, and offices need safe flooring to prevent client and staff member injuries. Our pendulum slip test guarantees compliance with security regulations.
2. Industrial & Storage Facility Facilities
High-traffic industrial environments more info require long lasting, slip-resistant flooring. ATTAR's slip testing services assist maintain work environment security.
3. Healthcare & Aged Care Facilities
Health centers and assisted living home need to minimize slip dangers. Our luminance contrast and slip resistance testing make sure safe mobility for patients and staff.
4. Public Facilities
Footpaths, train stations, and federal government structures require independent slip testing to satisfy availability and safety standards.
How ATTAR Carries Out Slip Resistance Testing
Action 1: Surface Area Assessment
We assess floor covering products and conditions (dry, wet, or polluted).
Action 2: Pendulum Slip Test (AS 4663)
Utilizing a slip test machine, we measure the vibrant coefficient of friction (DCOF).
Action 3: Wet Pendulum Test
Simulates slippery conditions to assess real-world slip dangers.
Step 4: Reporting & Compliance Accreditation
Detailed reports with R Rating or P Score tiles categories.
The Science Behind Pendulum Slip Testing
The pendulum test slip resistance approach includes a swinging arm with a rubber slider that mimics a foot's movement. The test steps:.
- Slip Prospective Worth (SPV).
- Pendulum ranking tiles category (P0 to P5).
Higher ratings (P4/P5) indicate better slip resistance.
Moisture Testing for Concrete Floors: Preventing Failures
Moisture-related floor covering failures can be pricey. ATTAR's concrete slab moisture testing consists of:.
- ASTM F2170 in-situ RH probes.
- Moisture meter for concrete check.
- Slab moisture test information analysis.
Conclusion
ATTAR (Advanced Technology Testing & Research) is Australia's relied on provider of slip resistance testing, floor slip resistance testing, concrete moisture testing, and luminance contrast assessments. With advanced technology like the pendulum slip test and moisture meter for concrete, we deliver accurate, independent, and compliant testing services.
Ensure your residential or commercial property satisfies security requirements-- contact ATTAR today:.
44/48 Rocco Dr, Scoresby VIC 3179, Australia.
+61 1300 139 155.
By picking ATTAR, you buy independent slip testing services, pendulum test slip resistance precision, and long-lasting floor security services. Let us assist you produce much safer, certified, and moisture-resistant environments. Report this page